BH-60 Fixed Gas Detector

BH-60 fixed gas detector adopts advanced catalytic gas sensor or electrochemical sensor, which can translate the gas concentration in the air to the digital signal output. The detector working with gas controller can be used to detect gas in refinery, chemical plant, LPG station, boiler room, painting plant and other places with gas exists. We provide gas detector OEM/ODM service.


TAG:  Boseanh2s gas detectorFixed gas detectorBH-60h2s fixed gas detector
Introduction

Detection principle:

The system provides 24V standard DC voltage to the external detector, collecting standard (4-20) mA input signal to analyze and complete the digital display and alarm operation.

Suitable for:

this fixed gas detector can be connected with control panel, alarm information would be display in the control panel by uploading 485 or (4-20) mA. Gas technical parameter settings shows as in Appendix 1.(For reference only, users can set parameters according to specific conditions.)

Gas Detected                                                                                             

Ex, O2, CO, H2S, CH4, NH3, CL2, HCL, H2, NO, NO2, NOX, CH2O, O3, CO2, SO2, ETO, PH3, HCN, N2, HF

Detection principle

catalytic or electrochemical or PID's or infrared principles

Sampling Method

wall, pipeline, flow-through (with the monitoring of the environment-related)

Resolution

1%LEL, 0.1ppm, 1ppm, 0.01%vol

Precision

<5% F.S.

Output signal

4-20mA ,0-5V, RS485, relays, wireless digital (optional)

 Response Time

≦30S 

Recovery Time ≦10S

Repeatability

≦±1% 

Linearity error

≦±1%

Zero shift                                            

≦±1% (FS / year) 

Display Technology

Display high brightness LED display

Connection mode

G1 / 2 male proof hose pipe thread size Thread size M45 * 2mm

Working temperature

-20℃-55℃ 

Explosion-Proof 

Ex db IIC T6 Gb

Working voltage

DC 24V

Dimensions

190×150×95mm

 Cable requirement

4-20mA, RVVP, 3-line, ≧1.5 mm2

Modbus, RVVP, 4-line, ≧1.5 mm2

 


TAG:  Boseanh2s gas detectorFixed gas detectorBH-60h2s fixed gas detector
Specifications

Note: Not all gases and range are listed, if you need more information, please contact us.

Model Range Resolution L-alarm H-alarm
CO 0-1000ppm 1ppm 50ppm 150ppm
O2 0-30%vol 0.1%vol 19.5%vol 23.5%vol
H2 0-1000ppm 1ppm 50ppm 150ppm
H2S 0-100ppm 0.1ppm 10ppm 20ppm
CH4 0-5%vol 0.01%vol 1%vol 2.5%vol
C2H4O 0-100ppm 1ppm 10ppm 20ppm
EX 0-100%LEL 1%lel/1%vol 20%LEL 50%LEL
HC 0-2%vol 0.01%vol 0 0
C2H6O 0-100ppm 1ppm 10ppm 20ppm
NH3 0-100ppm 1ppm 10ppm 20ppm
CL2 0-50ppm 0.1ppm 5ppm 10ppm
O3 0-20ppm 0.1ppm 5ppm 10ppm
SO2 0-20ppm 0.1 5ppm 10ppm
PH3 0-20ppm 0.1ppm 5ppm 10ppm
CO2 0-5%vol 0.01%vol 1%vol 2%vol
NO 0-250ppm 1ppm 50ppm 150ppm
NO2 0-20ppm 0.1ppm 5ppm 10ppm
HCN 0-50ppm 0.1ppm 5ppm 10ppm
HCL 0-50ppm 0.1ppm 5ppm 10ppm
HF 0-10ppm 0.1ppm 3ppm 5ppm
C7H8/C8H10 0-100ppm 1ppm 10ppm 20ppm

Note: Not all gases and range are listed, if you need more information, please contact us.


TAG:  Boseanh2s gas detectorFixed gas detectorBH-60h2s fixed gas detector
Inquiry

If you have any suggestions or opinions about our products, please leave a message, and we will immediately answer your questions. Thanks for your support.

*
*
*